Google Glass is a revolutionary smart eyewear device that integrates smart phone functions and requires no hands to operate. It has also been used in medical research in recent years. At present, the accuracy of using Google glasses for remote ECG transmission and diagnosis remains inconclusive, affecting its application in emergency medicine.
Jeroudi and Brilakis of the Texas Health Care System and the University of Texas Southwestern Medical Center, and the University of Texas Health Science Center's Foster School of Medicine conducted a study evaluating the use of Google Glass to remotely transmit ECGs. Research on the accuracy of diagnosis, research papers have been accepted by The American Journal of Cardiology.
The study selected 10 electrocardiograms from the book "The Complete Guide to ECGs", including anterior/inferior myocardial infarction, anterior myocardial infarction, complete left bundle branch block, pericarditis, and old inferior myocardial infarction. Infarction, Mohs type I atrioventricular block, paroxysmal supraventricular tachycardia, ventricular tachycardia, ventricular fibrillation and atrial flutter, a total of 21 features. The accuracy of the diagnosis was measured by scoring, and each feature was rated as 1 point. Only the main features were diagnosed to score, and the secondary features and diagnostic errors were not scored.
Twelve doctors read the electrocardiogram and gave a diagnosis in four different ways, namely, 1. Reading on the Google glasses screen; 2. Using the Google glasses camera (pictured on Figure 1) to take the ECG and put it on the mobile device (Apple) , iphone5, 4 inch display, 640 * 1136 pixel resolution, 326 pixels per inch. Figure 1 below) read; 3, directly read the paper ECG; 4, use the high-resolution camera to take the ECG and put it on the mobile device Read on.
Figure 1 Google Glass and reading ECG on a handheld device, above: Google Glass and its camera, below: Mobile devices reading ECG.
The results showed that the diagnostic scores after reading the ECG in the above four ways were 13.5 ± 1.8, 16.1 ± 2.6, 18.3 ± 1.7 and 18.6 ± 1.5 respectively. 9 doctors (75%) were not satisfied with the quality of the electrocardiogram displayed on the Google glasses screen, 10 A doctor (83%) believes that reading the ECG on the Google Glass screen is not reliable.
Figure 2 Average diagnostic score for each group, Glass Prism: Reading the ECG through the Google Glass screen; Glass Image: Using the camera of Google Glass to take a photo of the ECG and reading it on a mobile device; ECG: ECG.
For cardio-pulmonary resuscitation and general respiratory asphyxia patients needing emergency care. When the accident occurs, especially difficulty in breathing or the need to improve patient use of supplementary oxygen. Portable resuscitator, the first time in first aid and emergency use, you can quickly oxygen or unconscious persons CPR-BLS (the primary life-support) to facilitate the ready to immediately put into use, greatly increased hope of survival.
Feature:
It is semi-transparent and comes with a pressure limitation valve for patient safety
A textured surface ensuring a firm grip and providing effective ventilation.
Patient connector is 22/15mm.
100% latex free.
It is made of medical grade PVC/Silicone
Three sizes are available, suitale for adult, child and infant.
The accessories includes anesthesia mask(1),oxygen tubing(1),reservoir bag(1),opener(1) and airways(3).
Pvc Manual Resuscitator,Potable Resuscitator,Manual Ventilator Bag,Adult Manual Resuscitator